• UOP 481-09
Provide PDF Format

Learn More

UOP 481-09

  • Water in Liquid Hydrocarbons by Coulometry
  • standard by UOP LLC, A Honeywell Company, 04/01/2009
  • Publisher: UOP

$132.00$263.00


This method is for determining the water content of liquid hydrocarbons (naphtha, gasoline, kerosene, diesel), or other petroleum products (sulfolane and other solvents) that are liquid at room temperature using coulometric Karl Fisher titration. The lower limit of quantitation for the titrator is 10 µg of water. This results in an applicable concentration range for a sample of 10 mg/kg (mass-ppm) to 2 mass-% water.

Heavy hydrocarbons (insoluble oils and waxes) and other hydrocarbons that are viscous or solid at room temperature can be accommodated using a vaporizer for determining dissolved trace water and is applicable to samples over a concentration range of 20 mg/kg to 2 mass-% water.

Samples containing less than 500 mg/kg of water can be collected in prepared dry bottles or syringes as described in the Appendix.

Other applications for moisture and common interferences are discussed in Notes 1 and 2.

Related Products

UOP 678-04

UOP 678-04

Dissolved Molecular Oxygen in Liquid Hydrocarbons by Electrochemical Detection..

$110.00 $220.00

UOP 883-95

UOP 883-95

Purity of UOP No. 5 Inhibitor by Capillary Column GC..

$128.00 $256.00

UOP 456-80

UOP 456-80

Chlorides in Refinery Waters..

$128.00 $256.00

UOP 997-13

UOP 997-13

Hydrogen Content of Hydrocarbons by Low-Resolution Pulsed Nuclear Magnetic Resonance Spectrometry..

$110.00 $220.00